| Itemdetails | |||||||||
| HUBER+SUHNER Typ | 6500.42.0001 | ||||||||
| Termination Description | Precision Termination, Low Power | ||||||||
| Series / Configuration Highlights |
| ||||||||
| Itemnummer | 84000377 | ||||||||
| Data sheet | |||||||||
| 2002/95/EC (RoHS) | not compliant | ||||||||
| 2002/96/EC (WEEE) | no special marking needed | ||||||||
| Interface Standard1 | MIL-STD-348A/323 | ||||||||
| Elektrische Daten | Jump to [Top] | ||||||||
| Nominal Impedance1 | Interface SK - plug (male) | 50 | Ω | ||||||
| Average Power | to 30 °C ambient temperature linearly derated to 0 W at 85 °C ambient temperature Graph see below | 1 | W | ||||||
| Frequency range Frame | 0 to 40 | GHz | |||||||
| VSWR Frame | ≤ 1.22 | ||||||||
| Return Loss Frame | > 20.08 | dB | |||||||
| Mechanical data | Jump to [Top] | ||||||||
| Length Coaxial | 14.3 | mm | |||||||
| Environmental and general data | Jump to [Top] | ||||||||
| Operating Temp min | -55 | °C | |||||||
| Operating Temp max | 85 | °C | |||||||
| Storage Temp min | -55 | °C | |||||||
| Storage Temp max | 125 | °C | |||||||
| Weight | 0.0061 | kg | |||||||
| Material data | Jump to [Top] | ||||||||
| 2002/95/EC (RoHS) | not compliant | ||||||||
| 2002/96/EC (WEEE) | no special marking needed | ||||||||
| SK - plug (male) – Interface | |||||||||
| Piece part | Base material | Plating | |||||||
| Center contact | Copper Beryllium Alloy | SUCOPRO Plating | |||||||
| Outer contact | Copper Beryllium Alloy | SUCOPRO Plating | |||||||
| Insulator | PPO_PPE | ||||||||
| Heat sink body | Copper Beryllium Alloy | SUCOPRO Plating | |||||||
| Coupling nut | Stainless Steel | ||||||||
| Tests | Jump to [Top] | ||||||||
| Following tests have been passed successfully. For any details please contact your nearest HUBER+SUHNER representative. | |||||||||
| Test description | Specification / Paragraph / Method | ||||||||
| Thermal Shock | IEC 60169-1, Paragraph 16.4 | ||||||||
| Mechanical Shock | MIL-STD-202, Method 213, Condition I | ||||||||
| Vibration | MIL-STD-202, Method 204, Condition D | ||||||||